Vehicles & EVs
EV Charging Amps vs Circuit Breaker Amps
Two amp figures turn up in every home-charging conversation: the charger’s current and the breaker’s rating. They are related, but they are not the same number.
Ready to try the tool this guide describes?
Two different numbers
The charging current is what the charger delivers to the car, continuously, for hours. The breaker rating is the most the circuit is protected for. Because EV charging is a continuous load, the charger is normally set to draw no more than 80% of the breaker.
Breaker rating to charging current
Charging power below is at 240 V.
| Breaker | Maximum continuous charging current | Charging power |
|---|---|---|
| 20 A | 16 A | 3.84 kW |
| 30 A | 24 A | 5.76 kW |
| 40 A | 32 A | 7.68 kW |
| 50 A | 40 A | 9.6 kW |
| 60 A | 48 A | 11.52 kW |
Don’t apply the 80% twice
If you already know the charger’s current — say 32 A — that is the continuous current. Taking 80% of it again gives 25.6 A and 6.14 kW, which understates the real 7.68 kW. Apply the 80% only when you start from the breaker rating.
What this means for installation
Working backwards, a continuous 32 A load is usually paired with a 40 A circuit (125% of the current). Wire size, outlet type, panel capacity, and local rules all matter too. Have a licensed electrician size and install any charging circuit to your local electrical code.
Plug-in chargers
- A portable charger’s current setting must suit the outlet and circuit it is plugged into.
- Many portable chargers let you choose a lower current for older or shared circuits.
- Never raise a charger’s current above what its circuit is rated for.
Charging Amps vs Breaker Amps FAQ
- What is the 80% rule for EV chargers?
- Continuous loads such as EV charging are normally kept to 80% of the circuit breaker’s rating, so a 40 A breaker supports 32 A of charging.
- Is a 40-amp charger on a 40-amp breaker?
- Usually not — a charger drawing 40 A continuously is normally on a 50 A circuit. An electrician confirms it.
- Should I take 80% of my charger’s amp setting?
- No. The setting is already the continuous current. The 80% applies to the breaker rating.
- How many kW does a 60-amp breaker allow?
- Up to 48 A of charging, or 11.52 kW at 240 V, if the charger and car support it.
- Can I work out what breaker I need from this?
- Only as a rough guide. Circuit sizing depends on the charger, wiring, and local code, so an electrician should size it.
Related guides
- Charger Amps to KilowattsConvert EV charger amps to kilowatts with volts × amps ÷ 1,000, with a table for 120 V, 208 V, and 240 V chargers and what the car’s own limit changes.
- 32-Amp Charger PowerWhat a 32-amp EV charger delivers at 240 V and 208 V, how much energy and range an overnight session adds, and when the car limits it.
- 240V vs 120V SpeedHow much faster 240 V EV charging is than a 120 V outlet — the power ratio at common currents, and why the car’s charging limit can cap the gain.
Open the tool